Who Uses This Product? Physicians and physical therapists who want a flexible and time-saving method of delivering iontophoresis treatments to patients.
Why They Love It? The I-Bresis system allows patients to continue iontophoresis treatment independently without disrupting their daily activities while receiving a regulated, timed medication dosage. When the patch is used with the optional dose controller, the prescriber can choose from three treatment modes to regulate current delivery and treatment times.
Chattanooga I-Bresis Hybrid Iontophoresis System Overview
The Chattanooga I-Bresis System allows healthcare professionals to personalize iontophoresis medication delivery for their patients. This wireless system provides both mobility and flexibility for a time-saving treatment process. The system has three components: disposable patches; a rechargeable and optional Controller; and an optional Controller Charging Station. While the patches may be used on their own, the Controller enables two additional treatment modes with customizable currents: I-Bresis treatment and standard treatment. In I-Bresis mode, the device uses a three-minute Skin Conductivity Enhancement that breaks down the skin's resistance so medications can be fully absorbed. The patch then distributes positively or negatively charged water-soluble drugs through the skin.
Features and Benefits
- Controller-Activated I-Bresis Mode Breaks Down Skin's Resistance
- Three Treatment Modes With Controller: I-Bresis, Standard, and Patch-Only
- Personalized Dosage With Positively and Negatively Charged Drugs
- Wireless System Provides Mobility and Flexibility
- 4080 mA-Minute Treatment in Approximately One to Two Hours
- Built-In Batteries and Ergonomic Design Allow for Fast Application
- Optional Controller; Patch Functions Independently
- Optional Charging Station Available for Controller
Treatment Modes
I-Bresis Treatment: The I-Bresis Controller delivers a current of 3 mA to the I-Bresis Patch for three minutes during the Skin Conductivity Enhancement process. This is followed by the patient wearing the patch for one to two hours, resulting in a treatment of 4080 mA-minutes.
Standard Treatment: The I-Bresis Controller delivers a current of 2, 3, or 4 mA to the patch for 10 to 20 minutes, which results in a 40 mA-minute treatment. Repeat the same steps for an 80 mA-minute treatment.
Patch Treatment: For a 40 to 80 mA-minute treatment, the Patch delivers a low-level current over the span of two to four hours.


Contraindications
- Pregnancy
- Cardiac pacemakers or other implanted devices
- Sensitivity to the medication being administered
- Skin sensitivity to electrical currents or the solution being administered
- Recent scar tissue, damaged skin, or excoriated skin
- Head treatments on the orbital or temporal region


Frequently Asked Questions (FAQ)
What does the Controller do?
When the Controller is used in conjunction with the Patch, the Controller gives visual and audible indications of the treatment status and activates the I-Bresis and standard modes. Without the controller, administering medications can only be done in "patch-only mode." So, with the Controller, clinicians can select a customizable iontophoresis treatment plan for each individual patient.
What are the button functions on the Controller?
There are two basic buttons: the on/off switch and the start/pause button. The standard mode Button selects a standard treatment of 2, 3 or 4 mA per minute. The treatment selection can be changed while paused, during setup, or during the treatment.
Can the Patch be used without the Controller?
Yes, but the treatment cannot be customized without the Controller and functions in patch-only mode.
Product Specifications
- Manufacturer: Chattanooga
- Product Numbers: 5000060, 1360, 1361
- Patch
- Dose Capacity: 80 mA-Minute
- Usage: Single-Use, Disposable
- Number of Drug Pads: 2 (1 Positive, 1 Negative)
- Drug Pad Fill Volume: 1.5 Milliliters
- Controller
- Dimensions: 2.17 x 1.77 x .59 Inches
- Weight: 0.8 Ounce
- Dose Range: 040 mA-Minute
- Power Capacity (Fully Charged): Approximately 200 mA-minutes