About the size of a grocery bag, Eclipse can do it all - Up to 3 LPM continuous flow oxygen for nocturnal use, exercise, and other times when pulse flow just won't do
 - For times when pulse flow is the choice, the Eclipse has pulse settings from 1 to 6
- Runs on household AC current, DC from an auto accessory (lighter) outlet, or its internal auto-recharge power cartridge
- Rugged good looks; easy to use, easy to clean, easy to service
- Long service intervals for lower life-cycle costs
- A power miser, the low electrical consumption means less heat, noise and longer life
- Lightweight and easy to move, the Eclipse is the perfect home concentrator...and you can take it with you!
Peace of mind - Never run out of oxygen at home or in the car
- No concerns about storing oxygen in the home
- Self-monitoring alarm system
- Lower electric bills
- Small, lightweight, easily moved about, lifted up stairs or into an automobile
- Telescoping handle cart facilitates movement in or outside the home
- AC, DC and on-board auto recharge power cartridge enables longer excursion times; even extended overnight travel
Ease, Convenience, Quality of Life - No more waiting for oxygen deliveries
- Simple easy-to-use controls; no need to learn how to operate several devices
- Accurate, easy-to-read flow indicator
- Quiet operation without purge noise or pulse mode clicking
- Hi-tech, easy-to-clean non-medical look
- Compact and unobtrusive; no need to rearrange the room around it
Eclipse Oxygen System Specifications - Size: H x W x D 19.3 x 12.3 x 7.1 inches 49.0 x 31.2 x 18.0 cm
- Weight: With Power Cartridge 17.4 pounds (7.9 kg) Without Power Cartridge 13.9 pounds (6.3 kg)
 - Continuous flow settings: 0.5 to 3.0 LPM (0.5 liter increments)
- Oxygen concentration: 91% + 3% @ sea level
- Oxygen output pressure: 5.0 psig (34.5 kPa) nominal
- Pulse flow settings: 1.0 to 6.0 (0.5 increments)
- Trigger sensitivity: Adjustable between -0.25 cm H2O to -0.7 cm H2O
- Sound level: 48 dB(A) at 3.0 LPM continuous flow, 40 dB(A) at 3.0 pulse flow setting
Power specifications - AC Operation: 100 - 240 VAC, 50 - 60 Hz
- DC Operation: 12 V nominal
- Power Cartridge: 195 W-Hrs
Power Consumption - 48 watts at 1.0 LPM continuous flow
- 145 watts at 3.0 LPM continuous flow
- 38 watts at 1.0 pulse flow setting
- 85 watts at 6.0 pulse flow setting
Nominal Power Cartridge operating time - 4.0 hours at 1.0 LPM continuous flow
- 1.3 hours at 3.0 LPM continuous flow
- 5.1 hours at 1.0 pulse flow setting
- 2.3 hours at 6.0 pulse flow setting
Power Cartridge recharge time:1.4 to 5.0 hours, dependent upon the flow set setting, to achieve 80% capacity from a fully discharged Power Cartridge Back up alarm power: 9 Volt battery Oxygen concentration: - Green Light = Normal Operation
- Yellow Light = Warning or Caution
- Red Light Flashing = Abnormal Operation
Operating temperature: 50 F to 104 F (10 C to 40 C) at up to 28 C dew point, non-condensing Altitude operating range: 0 - 13,123 feet (0 - 4000 meters) Pulse flow settings 1.0 to 6.0 Trigger sensitivity Adjustable between-0.25 cm H2O to -0.7 cm H2O Altitude operating range 0-13,123 feet (0 - 4000 meters) | | | | Ac Power Supply and Power Cartridge | 10 Amp Switch Setting DC Power Supply | 15 Amp Switch Setting DC Power Supply | | Pulse Flow Setting | Bolus Size (+15%) | Min Breath Rate | Max Breath Rate | Max Breath Rate | Max Breath Rate | | 1.0 | 16ml | 6 | 40 | 40 | 40 | | 2.0 | 32ml | 6 | 40 | 40 | 40 | | 3.0 | 48ml | 6 | 40 | 40 | 40 | | 4.0 | 64ml | 6 | 39 | 31 | 39 | | 5.0 | 80ml | 6 | 31 | 25 | 31 | | 6.0 | 96ml | 6 | 26 | 20 | 26 | Alarms/Alerts - Loss of power
- Low Power Cartridge
- Low Therapeutic Oxygen Output
- Oxygen flow outside normal limits
- No inspiration detected in Pulse Flow
- Unit Malfunction
The Eclipse2 Oxygen System consists of: - Concentrator
- Power Cartridge
- AC Power Supply
- DC Power Supply
- Profile Cart with telescoping handle.
|